Ventis MX4
Overview
Configured for your safety, the Ventis MX4 takes your gas detection program to the next level.
- Detect from one to four gases with a wide range of sensor options
- Draw samples from up to 100 feet with an optional, integrated sampling pump
- Gain increased instrument visibility with a safety orange overmold
- Realize true portability with multi-gas protection in single-gas size
- Use the extended range battery for up to 20 hours (without pump)
- Discover a better way to do gas detection with the Ventis on iNet
Rugged and Reliable
This tough little unit has a high-impact polycarbonate housing and protective rubber overmold. The MX4 is also third-party certified IP66 and IP67. That means it is dust-tight to withstand the dirtiest environments. And, it is water resistant; passing both water jet and submersion tests.
Powerful Alarms
To warn users in hazardous areas, the unit uses a combination of three alarms: ultra-bright LEDs; 95 db audible alarm; and a powerful vibrating alarm.
iNet Compatible for Increased Safety, Cost Savings and Productivity
iNet is a software-based service that manages your fleet of gas detectors. iNet solves the most common gas detection problems. For example, iNet keeps people safe by providing visibility into alarms, exposure and usage. It keeps gas detectors working without costly and time-consuming maintenance.
Available sensors:
CH4, CO, H2S, LEL, NO2, O2
Case Material:
Polycarbonate with Protective Rubber Overmold
Dimensions:
103 mm x 58 mm x 30 mm (4.1” x 2.3” x 1.2”) - Ventis, Lithium-ion Battery
Version (typical)
172 mm x 67 mm x 66 mm (6.8” x 2.6” x 2.6”) - Ventis with Pump,
Lithium-ion Battery Version (typical)
Weight:
182 g (6.4 oz) - Ventis, Lithium-ion Battery Version (typical)
380 g (13.4 oz) - Ventis with Pump, Lithium-ion Battery Version (typical)
Operating Temperature Range:
-20°C- 50°C (-4°F-122°F) typical
Operating Humidity Range:
15%-90% non-condensing (continuous) typical
Display/Readout:
Backlit Liquid Crystal Display (LCD)
Power Source/Run Time:
Rechargeable Lithium-ion Battery Pack
(12 hours typical @ 20ºC) - Ventis
Rechargeable Extended-Range Lithium-ion Battery Pack
(20 hours typical @ 20ºC) - Ventis
(12 hours typical @ 20ºC) - Ventis with Pump
Replaceable AAA Alkaline Battery Pack
(8 hours typical @ 20ºC) - Ventis
(4 hours typical @ 20ºC) - Ventis with Pump
Alarms:
Ultra-bright LEDs, loud audible alarm (95 dB at 30 cm) and vibrating alarm
Sensors:
Combustible gases/methane – Catalytic Diffusion
O2, CO, H2S, NO2, SO2 - Electrochemical
Measuring Ranges:
Combustible Gases: 0-100% LEL in 1% increments
Methane (CH4): 0-5% of vol. in 0.1% increments
Oxygen (O2): 0-30% volume in 0.1% increments
Carbon Monoxide (CO): 0-1,000 ppm in 1 ppm increments
Hydrogen Sulfide (H2S): 0-500 ppm in 0.1 ppm increments
Nitrogen Dioxide (NO2): 0-150 ppm in 0.1 ppm increments
Sulfur Dioxide (SO2): 0-150 ppm in 0.1 ppm increments
Certifications:
UL
Class I, Division 1, Groups A B C D, T4
Class II, Groups F G (Carbonaceous & Grain Dust)
AEx d ia IIC T4
IP66
IP67
ATEX
Ex d ia I Mb / Ex d ia IIC T4 Gb;
Equipment Group and Category I M2 and II 2G
IP66
IP67
IECEx
Ex d ia IIC T4 Gb
IP66
IP67
CSA
Class I, Division 1, Groups A B C D, T4
C22.2 No. 152 for %LEL reading only
Ex d ia IIC T4
Measured Gases:
- Carbon monoxide (CO)
- Hydrogen sulfide (H2S)
- Methane (CH4)
- Oxygen (O2)
- Pentane (C5H12)